Have any questions? +49 221 6778932-0 or sales@flexypage.de

 

FloorInfo[video]

The FloorInfo widget displays videos depending on the floor. One video can be configured for each floor.

If a travel signal is switched on, the video of the current floor is played. When the video is finished, the system checks whether the elevator is still running (travel signal is present). If this is no longer the case, a signal configurable by the user can be output (e.g. "door open"). If the travel signal is still present, the video of the next stop is played. If this video is also played to the end, a new check is made to see whether the travel signal is still present. If this is not the case, the signal configured by the user is output. Otherwise, the system waits until the motion signal disappears and then outputs the signal configured by the user. The signal configured by the user is output for 500 ms each. It must be ensured that no new movement is started before the signal configured by the user has been triggered and that the signals Movement, Floor level, Next stop are available.
Software Stand: 
Widget Rating: 
0
No votes yet